Legacy and novel flame retardants from indoor dust in Antarctica: Sources and human exposure

Investor logo
Investor logo
Investor logo

Warning

This publication doesn't include Faculty of Education. It includes Faculty of Science. Official publication website can be found on muni.cz.
Authors

CORSOLINI Simonetta METZDORFF America BARONI Davide ROSCALES Jose L. JIMENEZ Begona CERRO-GALVEZ Elena DACHS Jordi GALBAN-MALAGON Cristobal AUDY Ondřej KOHOUTEK Jiří PŘIBYLOVÁ Petra POBLETE-MORALES Matias AVENDANO-HERRERA Ruben BERGAMI Elisa POZO Karla Andrea

Year of publication 2021
Type Article in Periodical
Magazine / Source Environmental Research
MU Faculty or unit

Faculty of Science

Citation
Web https://www.sciencedirect.com/science/article/pii/S001393512031241X?via%3Dihub
Doi http://dx.doi.org/10.1016/j.envres.2020.110344
Keywords PBDEs; HBCDs; Novel FRs; DPs; Antarctic research facilities; Dust
Description The air humidity in Antarctica is very low and this peculiar weather parameter make the use of flame retardants in research facilities highly needed for safety reasons, as fires are a major risk. Legacy and novel flame retardants (nFRs) including polybrominated diphenyl ethers (PBDEs), hexabromocyclododecanes (HBCDs), 1,2-bis(2,4,6tribromophenoxy) ethane (BTBPE), Dechlorane Plus (DP), and other nFRs were measured in indoor dust samples collected at research Stations in Antarctica: Gabriel de Castilla, Spain (GCS), Julio Escudero, Chile (JES), and onboard the RRS James Clark Ross, United Kingdom (RRS JCR). The GC-HRMS and LC-MS-MS analyses of dust samples revealed ?7PBDEs of 41.5 ? 43.8 ng/g in rooms at GCS, 18.7 ? 11.6 ng/g at JES, and 27.2 ? 37.9 ng/g onboard the RRS JCR. PBDE pattern was different between the sites and most abundant congeners were BDE-183 (40%) at GCS, BDE-99 (50%) at JES, and BDE-153 (37%) onboard the RRS JCR. The ?(4)HBCDs were 257 ? 407 ng/g, 14.9 ? 14.5 ng/g, and 761 ? 1043 ng/g in indoor dust collected in rooms at GCS, JES, and RRS JCR, respectively. The ?9nFRs were 224 ? 178 ng/g at GCS, 14.1 ? 13.8 ng/g at JES, and 194 ? 392 ng/g on the RRS JCR. Syn- and anti-DP were detected in most of the samples and both isomers showed the highest concentrations at GCS: 163 ? 93.6 and 48.5 ? 61.1 ng/g, respectively. The laboratory and living room showed the highest concentration of HBCDs, DPs, BTBPE. The wide variations in FR levels in dust from the three research facilities and between differently used rooms reflect the different origin of furnishing, building materials and equipment. The potential health risk associated to a daily exposure via dust ingestion was assessed for selected FRs: BDEs 47, 99, and 153, ?-, ?-, and ?-HBCD, BTBPE, syn- and anti-DP. Although the estimated exposures are below the available reference doses, caution is needed given the expected increasing use of novel chemicals without a comprehensive toxicological profile.
Related projects:

You are running an old browser version. We recommend updating your browser to its latest version.